A backflow preventer is a small device with a large job: it stops water in your pipes from flowing backwards into the public supply. It only works if it is tested and kept in repair, which is why many property owners are required to have it checked on a schedule.

Quick answer

Backflow occurs when water flows the wrong way through a plumbing system and can carry contaminants into the clean water supply. A backflow prevention assembly stops it. Irrigation systems, commercial buildings, fire lines and some other connections need one, and it generally has to be tested by a certified tester once a year and after any repair. If it fails, it is repaired or replaced and retested, and the report goes to the water authority.

Key takeaways
  • A backflow assembly protects the public water supply from your property's water.
  • Irrigation and commercial connections are the usual ones that need it.
  • Annual testing by a certified tester is the common requirement. Ask your water authority.
  • A failed test means repair or replacement and a retest.
  • Keep the test reports.

Why backflow happens

Pressure in a supply line can drop, for instance when a main breaks or a hydrant is used, and water from a connected system can be drawn backwards. A lawn sprinkler system, a boiler, a car wash or a connection to a chemical process can then contaminate the supply. The assembly closes valves in that situation.

Types of assemblies

  • Double check valve assembly: two check valves, used where the hazard is lower.
  • Reduced pressure zone assembly: a more protective design with a relief valve, used for higher hazards.
  • Pressure vacuum breaker: common on irrigation, installed above the highest sprinkler head.

Which type is required depends on the hazard and the local authority.

Who needs one

  • Properties with irrigation systems
  • Commercial buildings and many businesses
  • Fire sprinkler connections
  • Facilities with boilers, cooling systems or chemical use
  • Any property the water authority designates

What the test involves

A certified tester attaches gauges and runs through a set of checks on the shutoff valves, check valves and relief valve. The test often takes a short time when nothing is wrong. The tester records the results on a form and, where required, sends it to the water authority.

If it fails

  • The tester says what failed, such as a worn seal or a fouled check valve.
  • It is repaired or the assembly is replaced.
  • It is retested and the report filed.

Keep copies of every report. In some places failing to test brings fines or a shutoff notice, so ask what applies to you.

What to ask

  • Is the tester certified, and can they show it?
  • Do they file the report with the authority?
  • What does repair or replacement cost, and what does the retest include?

See our backflow preventer installation and repair page, and our property manager plumbing and commercial plumbing pages.

Frequently asked questions

How often must a backflow preventer be tested?

Usually once a year and after any repair, though the rule depends on your water authority.

Who can test one?

A tester certified for the work. Ask to see their credentials.

Does a home irrigation system need one?

Most do, and the rules depend on the city.

What if I never tested it?

Contact your water authority and have it tested. Some places issue notices or penalties.

How long does a test take?

Often short when nothing is wrong, longer if repairs are needed.